GB/T3836.1、GB/T3836.2、GB/T3836.3、IEC60079-0、IEC 60079-1、IEC 60079-7、EN60079-0、EN60079-1、EN60079-7

| Explosion-Proof Marking | Rated Voltage (V) | Rated Power (W) | Adjustment Method |
|---|---|---|---|
| Ex db eb IIC T6 Gb | 1,2,5,10,20,50,100 | 2 | Single-turn, Multi-turn |
1. This device consists of two parts: the core body and the knob head assembly;
2. The housing is injection-molded from high-quality imported engineering plastic or stainless steel;
3. This device is primarily designed for use with increased safety enclosures;
4. It must not be used independently in explosive gas environments;
5. This product is compatible with all explosion-proof electrical enclosures manufactured by our company;
6. Installation is top-mounted.




1. Suitable for Zone 1 and Zone 2 locations in explosive gas environments;
2. Suitable for Class IIA, IIB, and IIC explosive gas environments;
3. Suitable for Zone 21 and Zone 22 locations in explosive dust environments;
4. Suitable for Class IIIA, IIIB, and IIC explosive dust environments;
5. Suitable for temperature classes T1 to T6;
6. Suitable for hazardous environments in petroleum extraction, refining, chemical processing, power generation, offshore oil platforms, oil tankers, painting, metalworking, and similar applications.